Paint Booths & Finishing Systems · INTECH X500

INTECH X500 paint booth: the high-extraction base model

The base model of the higher-extraction class: a 7.5 kW turbine supply fan and a matching exhaust fan deliver 25,000+25,000 m³/h, with a pneumatic damper switching between paint and bake and a full-grille base. Aimed at the workshop running more than one shift or painting larger vehicles.

Overview

This model at a glance

25,000+25,000
Supply and exhaust air (m³/h)
7.5+7.5
Fan power (kW)
17
Electrical power (kW)
INTECH X500 paint booth, front three-quarter view
INTECH X500 paint booth, close-up of its main components
INTECH X500 paint booth, in use
INTECH X500 paint booth, wide view inside the workshop

Key features

What the standard supply includes

  • 7.5 kW turbine supply fan and 7.5 kW turbine exhaust fan at 650 Pa
  • pneumatic damper switching between paint and bake
  • round pressure gauge in the control box showing filter loading
  • full-grille base of five rows, 300 mm high
  • 50 mm flame-resistant EPS walls on a 0.426 mm steel skin
  • three-leaf 3000×2600 mm main door
  • 45° LED lighting: 32 ceiling and 12 side fittings at 20 W
  • argon-arc welded SUS304 heat exchanger and Riello G20 burner, 200,000 kcal/h

Engineering basis

What makes the difference in daily operation

Two turbine fans of equal capacity

A supply fan and an exhaust fan of 7.5 kW each move 25,000 m³/h in each direction, at an air speed of 0.28 m/s. Balanced supply and exhaust keep a steady flow from ceiling to grille floor, so overspray leaves the chamber instead of circling over the part.

A pneumatic damper and a filter gauge

The pneumatic damper moves the booth between paint and bake modes, and the pressure gauge in the control box shows when the filters start to load, so a filter is changed when it needs changing rather than on a calendar.

Specifications

INTECH X500 specification table

INTECH X500 Paint Booth specifications
SpecificationValue
Internal dimensions L×W×H (mm)6900×4000×2650
External dimensions L×W×H (mm)7000×5300×3400
Main door (mm)3000×2600
Main door typethree-leaf sheet metal
Work door (mm)800×2000 with observation glass and pressure relief above 10 Pa
Supply air (m³/h)25,000
Exhaust air (m³/h)25,000
Supply fanturbine fan, 7.5 kW
Exhaust fanturbine fan, 7.5 kW
Fan pressure (Pa)650
Air speed (m/s)0.28
Air changes per hour280
Damperpneumatic, switching paint and bake modes
Pressure gaugeround gauge in the control box showing filter loading
Filtrationnon-woven pre-filter (above 15 μm) · high-efficiency ceiling filter (over 98% of particles above 5 μm) · EU2 fibreglass floor filter
Lighting45° LED fittings: 32 ceiling and 12 side, 20 W each, ≥800 lux
Heater / burnerRiello G20 diesel burner
Heat output (kcal/h)200,000
Heat-up time5–7 minutes from 20 °C to 60 °C
Heat exchangerSUS304, argon-arc welded
Chimney (m)5
Wall type50 mm flame-resistant EPS panels, 0.426 mm steel skin
Base300 mm high, 40×80 galvanised tube · full grille (5 rows)
Control systempaint · paint with rising temperature · bake · temperature and time setting · lighting · alarm
Protectionemergency stop · over-temperature, overload and phase-loss protection · Schneider relays and contactors
Total power (kW)17
Voltage380 V 3-phase 60 Hz
Entry ramps (mm)550×2000, embossed plate

How it differs

How the INTECH X500 differs from its nearest model

Against the INTECH X300 and X360: 25,000+25,000 m³/h and 17 kW here, against 20,000+18,000 m³/h and 11 kW there, plus a pneumatic damper instead of an electric one, a filter pressure gauge and a full-grille base.

The INTECH X700 is the same booth with a four-leaf main door carrying large glass panels instead of the sheet metal door.

The 6900×4000×2650 mm chamber, the burner, the heat output and the ceiling filtration are the same across all INTECH models.

Browse the full Paint Booths & Finishing Systems family

Industries

Sectors this model serves

These are the industries the INTECH X500 serves specifically, not the family as a whole.

FAQ

Common questions about the INTECH X500

What is the airflow of the INTECH X500 paint booth?

25,000 m³/h of supply air and 25,000 m³/h of exhaust air, from two 7.5 kW turbine fans at 650 Pa.

What does the pneumatic damper on the INTECH X500 do?

It switches the air path between paint and bake modes. The damper is pneumatic on the INTECH X500, X700, X900 and X960, and electric on the INTECH X300 and X360.

What electrical supply does the INTECH X500 need?

17 kW on a 380 V, 3-phase, 60 Hz supply.

How does the INTECH X500 differ from the INTECH X700?

Only in the main door: three-leaf sheet metal here, four-leaf with large glass panels on the INTECH X700. Air, power and control are identical.

How is the INTECH X500 heated?

By a Riello G20 diesel burner rated at 200,000 kcal/h through an argon-arc welded SUS304 exchanger, from 20 °C to 60 °C in 5 to 7 minutes.

Request a quote for the INTECH X500 Paint Booth

State your sector and workshop size in the form, and you receive a quote built on the configuration that fits your site rather than a generic one.