Paint Booths & Finishing Systems · INTECH X300
INTECH X300 paint booth: the entry point to the INTECH range
A 6900×4000×2650 mm chamber with 50 mm EPS walls, two centrifugal supply fans delivering 20,000 m³/h, a 4 kW exhaust fan pulling 18,000 m³/h and a Riello G20 diesel burner. Built for the repair workshop or collision centre that paints one vehicle per cycle on an 11 kW supply.
Overview
This model at a glance




Key features
What the standard supply includes
- 50 mm flame-resistant EPS walls on a 0.326 mm steel skin
- three-leaf 3000×2600 mm main door, EPS-filled, with an observation window
- two 3 kW centrifugal supply fans and a 4 kW exhaust fan at 600 Pa
- electric damper switching between paint and bake
- high-efficiency ceiling filter holding over 98% of particles above 5 μm
- 300 mm base: 3 rows of embossed plate and 2 rows of grille
- 45° LED lighting: 32 ceiling and 12 side fittings at 18 W
- argon-arc welded SUS304 heat exchanger and Riello G20 burner, 200,000 kcal/h
Engineering basis
What makes the difference in daily operation
More supply air than exhaust air
The booth brings in 20,000 m³/h and extracts 18,000, so the chamber sits at a slight positive pressure that keeps workshop dust from creeping in during spraying. An air speed of 0.25 m/s at 280 changes per hour carries overspray off the vehicle for the whole cycle.
From 20 °C to 60 °C in minutes
The Riello G20 burner, rated at 200,000 kcal/h through an argon-arc welded SUS304 exchanger, brings the chamber to baking temperature in 5 to 7 minutes, and a 5 m chimney carries combustion gases clear of the workshop roof.
Specifications
INTECH X300 specification table
| Specification | Value |
|---|---|
| Internal dimensions L×W×H (mm) | 6900×4000×2650 |
| External dimensions L×W×H (mm) | 7000×5300×3400 |
| Main door (mm) | 3000×2600 |
| Main door type | three-leaf sheet metal, EPS-filled, with a square observation window |
| Work door (mm) | 800×2000 with observation glass and pressure relief above 10 Pa |
| Supply air (m³/h) | 20,000 |
| Exhaust air (m³/h) | 18,000 |
| Supply fan | two centrifugal fans, 2×3 kW |
| Exhaust fan | 4 kW fan |
| Fan pressure (Pa) | 600 |
| Air speed (m/s) | 0.25 |
| Air changes per hour | 280 |
| Damper | electric, switching paint and bake modes |
| Filtration | non-woven pre-filter (above 15 μm) · high-efficiency ceiling filter (over 98% of particles above 5 μm) · EU2 fibreglass floor filter |
| Lighting | 45° LED fittings: 32 ceiling and 12 side, 18 W each, ≥800 lux |
| Heater / burner | Riello G20 diesel burner |
| Heat output (kcal/h) | 200,000 |
| Heat-up time | 5–7 minutes from 20 °C to 60 °C |
| Heat exchanger | SUS304, argon-arc welded |
| Chimney (m) | 5 |
| Wall type | 50 mm flame-resistant EPS panels, 0.326 mm steel skin |
| Base | 300 mm high, 40×80 galvanised tube · 3 rows of embossed plate and 2 rows of grille |
| Control system | paint · paint with rising temperature · bake · temperature and time setting · lighting · alarm |
| Protection | emergency stop · over-temperature, overload and phase-loss protection · Schneider relays and contactors |
| Total power (kW) | 11 |
| Voltage | 380 V 3-phase 60 Hz |
| Entry ramps (mm) | 550×2000, embossed plate |
How it differs
How the INTECH X300 differs from its nearest model
The INTECH X360 is the same booth with identical air and power figures (20,000+18,000 m³/h, 11 kW); it differs in the wall, ROCKWOOL instead of EPS, and in a base with three rows of grille instead of two.
The INTECH X500 raises the air to 25,000+25,000 m³/h with two 7.5 kW turbine fans, and adds a pneumatic damper, a filter pressure gauge and a full-grille base, on 17 kW.
The 6900×4000×2650 mm chamber, the burner, the heat output and the ceiling filtration are the same across all INTECH models.
Industries
Sectors this model serves
These are the industries the INTECH X300 serves specifically, not the family as a whole.
FAQ
Common questions about the INTECH X300
What is the air capacity of the INTECH X300 paint booth?
Two 3 kW centrifugal supply fans deliver 20,000 m³/h and a 4 kW exhaust fan extracts 18,000 m³/h, at 600 Pa and an air speed of 0.25 m/s inside the chamber.
What electrical supply does the INTECH X300 need?
Total power is 11 kW on a 380 V, 3-phase, 60 Hz supply.
How is the INTECH X300 heated?
By a Riello G20 diesel burner rated at 200,000 kcal/h through an argon-arc welded SUS304 heat exchanger, taking the chamber from 20 °C to 60 °C in 5 to 7 minutes.
How does the INTECH X300 differ from the INTECH X360?
Only in the wall and the base: 50 mm EPS here against ROCKWOOL on the INTECH X360, and a base of three embossed rows and two grille rows here against two embossed rows and three grille rows there. The air and power figures are identical.
What filtration stages does the booth use?
Three: a non-woven pre-filter at the air intake holding particles above 15 μm, a high-efficiency ceiling filter holding over 98% of particles above 5 μm, and an EU2 fibreglass floor filter that catches overspray before exhaust.
Request a quote for the INTECH X300 Paint Booth
State your sector and workshop size in the form, and you receive a quote built on the configuration that fits your site rather than a generic one.