Prep Stations & Mixing Rooms · INTECH PURE 120

INTECH PURE 120 prep station: an open bay with no cabin

No walls and no curtains: a 3450×1100×2000 mm extraction cabinet placed at the end of the bay, with a 5.5 kW centrifugal fan drawing 15,000 m³/h at 800 Pa through multi-layer fibreglass filters and activated carbon. Aimed at the workshop working on parts that do not fit an enclosed room, or wanting a prep area without building works.

Overview

This model at a glance

15,000
Air capacity (m³/h)
5.5
Fan power (kW)
800
Fan pressure (Pa)
INTECH PURE 120 open prep station, front three-quarter view
INTECH PURE 120 open prep station, close-up of its main components
INTECH PURE 120 open prep station, in use
INTECH PURE 120 open prep station, wide view inside the workshop

Key features

What the standard supply includes

  • open station with no cabin and no curtains
  • 3450×1100×2000 mm extraction cabinet
  • 5.5 kW centrifugal exhaust fan, 15,000 m³/h at 800 Pa
  • multi-layer fixed fibreglass filters
  • activated carbon layer for vapours
  • four straight ducts and one elbow to route the exhaust
  • control box with run and lighting switch, emergency stop and fault alarm

Engineering basis

What makes the difference in daily operation

An open bay that does not cap part size

The station is an extraction and filter cabinet at the end of the bay, and the part comes in from the open side. No wall limits its length and no curtain needs hanging, and the bay stays usable for other work when no prep is running.

Pressure enough for the exhaust run

The centrifugal fan develops 800 Pa, which keeps extraction steady through four ducts and an elbow to the end of the run, while the fibre layers hold sanding dust and the activated carbon treats vapours before exhaust.

Specifications

INTECH PURE 120 specification table

INTECH PURE 120 Open Prep Station specifications
SpecificationValue
Typeopen prep station with no cabin
Fan cabinet L×W×H (mm)3450×1100×2000
Fancentrifugal exhaust fan, 5.5 kW
Air capacity (m³/h)15,000
Fan pressure (Pa)800
Fan speed (rpm)900
Filtrationmulti-layer fixed fibreglass filters · activated carbon
Ductingfour straight ducts and one elbow
Control boxrun and lighting switch · emergency stop · fault alarm
Total power (kW)5.5
Voltage380 V 3-phase 60 Hz

How it differs

How the INTECH PURE 120 differs from its nearest model

The PURE 200 is an enclosed 6900×4000×2650 mm room with PVC curtains, a rear wall and a high-efficiency ceiling plenum, on a 4 kW turbine fan.

The PURE 360 and 500 are down-draft rooms on a metal base, the second with both supply and exhaust fans.

The 15,000 m³/h air capacity is the same here as on the fan of the enclosed PURE rooms.

Browse the full Prep Stations & Mixing Rooms family

FAQ

Common questions about the INTECH PURE 120

Does the PURE 120 need walls or curtains?

No. It is an open station: an extraction and filter cabinet placed at the end of the bay, with the part coming in from the open side.

What is the air capacity of the PURE 120 prep station?

15,000 m³/h from a 5.5 kW centrifugal exhaust fan at 800 Pa and 900 rpm.

How are vapours treated on the PURE 120?

By an activated carbon layer after the multi-layer fibreglass filters, so volatile vapours are treated before they leave through the ducts.

How does the PURE 120 differ from the PURE 200?

The PURE 200 is an enclosed room with curtains, a rear wall and a high-efficiency ceiling plenum; the PURE 120 is an open station with fibreglass and activated carbon filtration. Both move 15,000 m³/h.

What electrical supply does the PURE 120 need?

5.5 kW on a 380 V, 3-phase, 60 Hz supply.

Request a quote for the INTECH PURE 120 Open Prep Station

State your sector and workshop size in the form, and you receive a quote built on the configuration that fits your site rather than a generic one.